KC-140
HPLC KC-140 Series
A modular HPLC system with a quaternary pump, a 120-vial autosampler, a column compartment and a choice of UV, DAD, FLD or RID detectors. It runs on Smartlab CDS software, which includes an audit trail for regulatory compliance.
Key Features
Key features will be available soon. Contact our team for more information.
Technical Specifications
System
- Configuration: Modular HPLC system
- Modules: SO-140 Solvent Organizer, PQ-140 Quaternary Pump, AS-140 Autosampler, CO-140 Column Compartment and DAD-140 Detector
- Optional Detectors: UV, DAD, FLD or RID
- Software: Smartlab CDS Workstation, all-digital multi-channel signal acquisition with regulatory compliance features and an audit trail
Pump
- Flow Range: 0.0000–10.0000 mL/min
- Minimum Flow Resolution: 0.0001 mL/min
- Flow Precision: RSD ≤0.08% (at 1 mL/min, ultrapure water, 10 MPa, room temperature)
- Flow Accuracy: ±0.2% (same test conditions as flow precision)
- Pressure Limit: 45 MPa at 0.0001–2.0000 mL/min; 30 MPa above 2.0000 mL/min
- Gradient Accuracy: ±1% (national standard method, 5–95%, 0.2–2.0 mL/min)
- Dimensions (H x W x D): 470 x 325 x 150 mm
Autosampler
- Sample Capacity: 120 vials (2 trays x 60 x 2 mL vials)
- Injection Reproducibility: <1.0 %RSD for 0.5–1.9 µL; <0.3 %RSD for 2.0 µL and above
- Linearity: ≥0.9999
- Carry-over (Cross Contamination): ≤0.006%
- Maximum Working Pressure: 45 MPa
- Sample Cooling (optional): Down to 4°C minimum
- Dimensions (L x W x H): 495 x 360 x 370 mm
Column Compartment
- Temperature Setting Range: 4–80°C
- Temperature Control Range: +5 to +60°C
- Temperature Stability: ±0.04°C
- Temperature Accuracy: ±0.01°C
- Dimensions (L x W x H): 360 x 155 x 560 mm
UV Detector
- Light Source: Deuterium lamp
- Wavelength Range: 188–740 nm
- Noise: 1.0x10⁻⁵ Au (1 mL/min, methanol, C18 column)
- Flow Cell Volume: 10 µL
DAD Detector
- Spectral Range: 190–800 nm
- Baseline Noise: ≤4x10⁻⁵ Au
- Baseline Drift: ≤3x10⁻⁵ Au/h
- Minimum Detectable Concentration: ≤2x10⁻⁸ g/mL
FLD Detector
- Spectral Range: 200–650 nm
- Baseline Noise: ≤5x10⁻⁶ FU
- Minimum Detectable Concentration: ≤3x10⁻¹⁰ g/mL (naphthalene/methanol)
RID Detector
- Refractive Index Range: 1.00–1.75
- Noise: ≤2.5 nRIU
- Cell Volume: 8 µL
Power and Environment
- Power Supply: 100–240 VAC, 50 Hz
- Operating Temperature and Humidity: 4–35°C, 45–85% humidity
- Storage Temperature and Humidity: 4–55°C, <93% humidity
Applications and Use Cases
-
Biochemistry & Life Sciences
-
Environmental & Water Science
-
Food & Beverage
-
Pharmaceuticals & Medicines