TENSA-TD
TENSA TD Series UPS
A low-frequency online UPS from 3 to 500 kVA, with an output isolation transformer and DSP digital control. It keeps laboratory instruments running where the mains supply is unreliable, and its status can be monitored remotely through a mobile app.
Key Features
- Unreliable mains power: Keeps supplying the load when the mains voltage is too high or too low, or when there are surges, harmonic distortion or frequency swings
- Load protection: Transfers to bypass on overload, with dedicated short-circuit protection
- Remote monitoring: Input and output data, load condition and battery voltage can be monitored in real time through a mobile app; one terminal covers up to 256 UPS units
Technical Specifications
General
- Manufacturer: TENSA
- Type: Low-frequency online UPS with an output isolation transformer
- Control: Full digital DSP control and full microprocessor control, with no-break static and manual bypass
- Display: Large LCD and LED, bilingual Chinese and English
- Efficiency: 93–94% (over 97% in ECO mode)
- Features: DC cold start, intelligent battery charging (1–25 A adjustable current), adaptive frequency and phase sequence, dedicated short-circuit protection, IGBT technology and dual AC input (main and bypass)
- Monitoring: A mobile monitoring card shows UPS data in real time through an app; one remote terminal can monitor up to 256 UPS units
Input
- Input Voltage: 220 Vac ±25% (TD11); 380 Vac ±25% (TD31, TD33)
- Input Frequency: 40–70 Hz (adjustable)
- Bypass Input: 220 Vac ±25% (TD11, TD31); 380 Vac ±25% (TD33)
Output
- Output Voltage: 220 Vac (TD11, TD31); 380 Vac line voltage (TD33)
- Static Voltage Accuracy: ±2%
- Dynamic Voltage Transient: ≤9%
- Output Waveform Distortion: ≤3% (linear load), ≤8% (non-linear); TD33 250 kVA and above ≤3% (linear), ≤5% (non-linear)
- Power Factor: 0.8
- Output Frequency: 50 Hz / 60 Hz
- Overload: Warning starts at 105%±5%; the UPS transfers to bypass after 2 minutes (105–125%), 30 seconds (125–150%) or 500 ms (above 150%)
Battery and Environment
- Battery Voltage: 192 Vdc (up to 20 kVA); 384 Vdc; 480 Vdc; 768 Vdc (500 kVA)
- Operating Temperature: 0 to 40°C
- Operating Humidity: 20–95% (non-condensing)
TD11 - Single phase in, single phase out
- Capacity: 3 kVA/2.4 kW, 6 kVA/4.8 kW, 10 kVA/8 kW, 15 kVA/12 kW, 20 kVA/16 kW
- Dimensions (L x W x H): 533 x 260 x 501 mm (3 kVA) to 655 x 370 x 900 mm (15–20 kVA)
- Weight: 40 kg (3 kVA) to 152 kg (20 kVA)
TD31 - Three phase in, single phase out
- Capacity: 10 kVA/8 kW, 15 kVA/12 kW, 20 kVA/16 kW, 30 kVA/24 kW, 40 kVA/32 kW
- Dimensions (L x W x H): 560 x 260 x 717 mm (10 kVA) to 830 x 515 x 1135 mm (40 kVA)
- Weight: 79.5 kg (10 kVA) to 285 kg (40 kVA)
TD33 - Three phase in, three phase out
- Capacity: 10 kVA to 500 kVA (8 kW to 400 kW)
- Dimensions (L x W x H): 830 x 455 x 1055 mm (10–30 kVA) to 2100 x 1100 x 2000 mm (500 kVA)
- Weight: 208 kg to 3660 kg
Applications and Use Cases
Applications and use cases will be available soon. Contact our team for more information.