SSA-100
Atomic Absorption Spectrophotometer SSA-100 Series
The fifth-generation AAS from Adhyascientific. It supports three atomization methods (flame, graphite furnace and hydride) that switch automatically within one second. It comes with dual-beam optics, 8 lamps, an autosampler and software with ready-made parameters for each element.
Key Features
Key features will be available soon. Contact our team for more information.
Technical Specifications
General and Optics
- Generation: Fifth-generation AAS (Atomic Absorption Spectrophotometer) from Adhyascientific
- Optical System: Optical dual-beam for flame; electronic dual-beam for graphite furnace
- Wavelength Range: 185.0–910.0 nm
- Monochromator: Czerny-Turner with aberration correction
- Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0 nm (switches automatically)
- Detector: Photomultiplier tube (PMT)
- Background Correction: Deuterium lamp
- Lamp Turret: 8 lamps on at the same time; each element's lamp is recognised automatically by barcode
Measurement Methods
- Analysis Techniques: Flame, graphite furnace, hydride generation and flame emission
- Quantitation Methods: Calibration curve and standard addition
- Repeat Measurements: Up to 99
- Reading Mode: Peak height or peak area
- QA/QC: Correlation coefficient, RSD%, QC samples, blanks and more
Atomization and Flame
- Atomization System: Flame, graphite furnace and hydride mounted in parallel; switches automatically within one second
- Burner Head: Pure titanium, 10 cm
- Atomizer: High-efficiency glass atomizer that resists hydrofluoric acid
- Spray Chamber: Polypropylene
- Position Adjustment: Motor-driven and automatic
- Gas Controller: Mass flow controllers
- Safety: Acetylene leak alarm, flame monitoring protection, acetylene and air pressure alarms, air buffer tank and waste liquid level monitoring
Graphite Furnace
- Heating Temperature Range: Room temperature to 3000°C
- Heating Method: RAMP / STEP
- Heating Control: Drying is current-controlled; ashing and atomization are controlled by optical temperature
- Heating Program: Up to 20 steps; internal gas flow 0–1 L/min
- Graphite Tube: Pyrolytic-coated, platform or non-pyrolytic options
- Gas: Argon 0.35–0.50 MPa
- Cooling Water: 10–30°C, pressure 0.06–0.2 MPa, flow 0.5–2 L/min
- Power Requirements: 220 V ±10%, 50 ±1 Hz, maximum power 6000 W
- Protection: Gas pressure monitoring, overcurrent protection, cooling block temperature protection and cooling water flow monitoring
- Features: Pneumatic furnace, in-furnace observation camera and digital light control with one-touch temperature calibration
Furnace Autosampler
- Injection Positions: 100 + 8 positions; standards, samples, matrix modifiers and diluents can go in any position
- Injection Volume: 1–100 µL
- Result Reproducibility: ≤1.5%
- Features: Fits and removes in just 3 seconds; supports online dilution
HVG-A Hydride Generator
- Elements: As, Hg, Pb, Se, Bi, Sb, Te
- Injection Flow Rate: Adjustable in 10 levels
- Detection Limit: Hg 5 ppb, As 10 ppb
Software
- Software: Preset parameters for each element, one-click module configuration, automatic dilution and smart sample sequence coding
Applications and Use Cases
-
Environmental & Water Science
-
Food & Beverage
-
Pharmaceuticals & Medicines